Research of design of solar dryer with evacuated tube collector for drying coffee bean has been done. Open sun drying is the best but has the disadvantages such as drying temperature is relatively equal to ambient, low cleanliness and require a wider area. The flat plate collector type solar drying is one of the simplest forms of solar dryers but the obtained drying temperature is still lower than 55°C. To increase the drying temperature it is necessary to collector type which is more absorb solar radiation and store it so that it can minimize the heat loss. One type of collector that can do this is the evacuated tube collector. The advantage of this collector is the higher air drying temperature so that the drying rate increases and the drying time is shorter than the flat plate collector type. Test results of a solar dryer designed then is being used for drying coffee bean (moisture content  from 52.80% to 12.30%), with forced convection system which the air speed are varied of 2-6 m/sec. During the drying process, the average weather conditions are in the range 143-855 Watt / m2, ambient temperature of 28-36°C. The air temperature in the collector are 85-192°C and the temperature in the drying chamber are 35-78°C. The results showed that air drying velocity is directly proportional to the drying rate and collector efficiency but inversely to drying time and specific energy consumption (SEC).


Keywords


Dryers; Collector; Evacuated Tube; Performance;

Full Text:

PDF (Indonesian)

References


Darshit, P. dan G.D. Agawal, 2011, Solar Drying in Hot and Dry Climate of Jaipur, India, International Journal of Renewable Energy Research, 1(4): 224-231

Fudholi A., K. Sopian, M.H. Ruslan, M.A. Alghoul, M.Y. Sulaiman, 2010, Review of Solar Dryer for Agricultural and Marine products, Renewable and Sustainable Energy Reviews, 14: 1-30.

Hossain, M.S., Saidur, R., Fayaz, H., Rahim, N.A., Islam, M.R., Ahamed, J.U., and Rahman, M.M., 2011, Review on Solar Water Heater Collector and Thermal Performance of Circulating Pipe, Renewable and Sustainable Energy Reviews, vol. 15: 3801-3812.

Lamnatou C., Papanicolaou E., Belessiotis V., Kyriakis N., 2012, Experimental Investigation and Thermodynamic Performance Analysis of a Solar Dryer Using an Evacuated-Tube Air Collector, Applied Energy, vol 94: 232-243.

Saravanakumar, P.T. and K. Mayilsamy, 2010, Forced Convection Flat Plate Solar Air Heaters With and Without Thermal Storage, Journal of Scientific and Industrial Research, 69: 966-968.

Sundari Umayal A.R., Neelamegam P., Subramanian C.V., 2013, Performance of Evacuated Tube Collector Solar Dryer with and without Heat Sources, Iranica Journal of Energy & Environment 4 (4): 336-342.

Venkatesan N, Arjunan T.V., 2014, An Experimental Investigation and Performance Analysis of a Solar Drying of Bitter Gourd Using an Evacuated-Tube Air Collector, International Journal of Chem Tech Research, Vol. 6, No. 14: 5510-5518

Zhiqiang, Y., Development of Solar Thermal Systems in China, Solar Energy Materials & Solar Cells, Vol. 86: 427-442


Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.