Wastewater Treatment Efficiency Using Up flow Anaerobic Filter and Activated Sludge Acclimatization

Uray Lusiana

Abstract


One of the largest applications of detergent is for cleaning clothes. By society, waste water containing detergent dumped directly into the ground or river. This can lead to pollution of soil or river so that can degrade the quality of the environment. Wastewater treatment has been carried out by the community one of them using the well diffusion because it is cheap. The downside of this treatment is not suitable to be applied in areas with high groundwater level and swampy areas. This study aims to determine the efficiency of wastewater treatment by anaerobic filter and up flow detergent acclimatization activated sludge. Anaerobic system is a biological process that uses the activity of microorganisms that can grow and live in environments without oxygen. Anaerobic bacteria living in the stone surface and oxidized past wastewater. The method used was neutralized waste water until the pH 7 followed by adding it to anaerobic tank and closed.  Inside anaerobic tank occurred inoculation by activated sludge and remaining it until 6 days. The temperature then must be watched between 37oC – 40oC in order of successfully acclimatization and it’s indicated by formation of gas. After acclimatization, the wastewater in anaerobic tank was stream down to up flow anaerobic filter through bottom to the top of the tank. The sample was then retaining in 2, 4, 6, 8, 10, 12 and 14 days followed by the detergent content analysis. The result showed that it could degrade the detergent rate from 21,03 mg/L to 3,83 mg/L  and the efficiency until 81,8 % with the maximum retention time was 14 days.

Full Text:

PDF

References


Anonimous, 2009. Tangki Septic-Filter up flow Pereduksi Deterjen. Kompas, Kamis, 23 Februari 2006.

Betty dan Rahayu, 1995, Penanganan Limbah Industri Pangan, Kanisius, Yogyakarta.

Benefild dan Randall, 1979, Biological Process Design for Wastewater Treatment, Virginia Polytechnic Institute and State University, New York.

Buchari, I Wayan Arka, K. G. Dharma Putra dan I G. A. Kunti Sri Panca Dewi, 2001, Kimia Lingkungan, UPT Udayana, Bali.

Chatib B, 1998, Pengolahan Air Limbah Secara Biologi, ITB, Bandung.

Fardiaz, 1992, Polusi Air dan Udara, Kanisius, Yogyakarta.

Fair, G.M. Geyer.J.C. Okun.D.A, 1968, Waste and wastewater Engineering, Vol.2, John Wiley and Sons Inc, New York.

Mara D., 1978, Sewarage Treatment in Hot Climates, Wiley & Sons, New York.

Ryadi S., 1984, Pencemaran Air, Karya Anda, Semarang.

Salvato J.A, 1992, Environmental Engineering and Sanitation, A. Willey Interscience Publication, John Wiley & Sons, Inc., New York.

Suastuti Adhi Dwi Ni G. A. M, 2008. Efektifitas Penurunan Kadar Dodesil Benzen Sulfonat (DBS) dari Limbah deterjen yang di Olah dengan Lumpur Aktif, FMIPA, Universitas Udayana, Bukit Jimbaran, Bali.

Titistiti dan Hadi, 2010. Pengaruh Roughing Filter dan Slow Sand Filter dalam Pengolahan Air Minum dengan Air Baku dari Intake Karangpilang Terhadap Parameter Kimia, Jurusan Teknik Lingkungan-FTSP-ITS.

Wardhana W.A, 1995, Dampak Pencemaran Lingkungan, Andi Offset, Yogyakarta.

Wignyanto. Dkk, 2008. Teknik Baru Cara Peningkatan Efektifitas dan Efisiensi Kemampuan Biodegradasi Surfaktan Deterjen Alkylbenzene Sulfonate, F-MIPA Unibraw, Malang.

Waluyo L., 2005, Mikrobiologi Lingkungan, UMM, Malang.




DOI: http://dx.doi.org/10.36974/jbi.v2i1.719

Refbacks

  • There are currently no refbacks.


BIOPROPAL Industri

Published by :

Institute for Industrial Research and Standardization (Baristand Industri) in Pontianak

Agency for Industrial Research and Development, Ministry of Industry 

Jl. Budi Utomo No. 41 Pontianak, West Kalimantan, Indonesia

Tel / Fax : +62 561 881393, 881533

email      : biopropal.industri@gmail.com

 

BIOPROPAL Industri indexed in: 

Hasil gambar untuk gambar doajHasil gambar untuk gambar google scholar

RJI Main logo